Problem Overview
We evaluate the boundary behavior of contaminant solute flux J(r)=βD0βrln(r/R0β) as radial distance rβ0+ where D0β=1.80Β g/(mβ
day) and R0β=100.0Β m. Direct substitution yields the indeterminate product form 0β
(ββ). We convert the expression to a quotient, evaluate the limit using L'HΓ΄pital's Rule, determine peak flux location rβ, and interpret results for groundwater filter pack design.
Step-by-Step Mathematical Solution
Step 1: Algebraic Inversion & L'HΓ΄pital's Rule Evaluation
The governing formulation is L'HΓ΄pital's Rule for Indeterminate Forms:
xβalimβg(x)f(x)β=xβalimβgβ²(x)fβ²(x)β
(This formula and transformation techniques are defined in Indeterminate Forms and L'HΓ΄pital's Rule.)
Classify the Indeterminate Form:
As rβ0+:
rβ0,100rββ0+βΉln(100rβ)βββ
Thus, the product rln(r/100) produces the indeterminate form 0β
(ββ).
Invert to a Fractional Quotient:
To apply L'HΓ΄pital's Rule, keep the logarithmic term in the numerator and push the linear factor r to the denominator as rβ1=r1β:
rβ0+limβJ(r)=βD0βrβ0+limβrβ1ln(r/100)β
Direct substitution now yields the form ββββ, which grants a green light for L'HΓ΄pital's Rule.
Differentiate Numerator and Denominator Independently:
Numerator derivative using the Chain Rule:
drdβ[ln(100rβ)]=100rβ1ββ
1001β=r1β
Denominator derivative using the Power Rule:
drdβ[rβ1]=βrβ2=βr21β
Simplify Algebraically and Evaluate:
rβ0+limββr21βr1ββ=rβ0+limβ[r1ββ
(βr2)]=rβ0+limβ(βr)=0
Multiplying by the constant βD0β:
Jboundaryβ=rβ0+limβJ(r)=βD0ββ
(0)=0.00Β g/(mβ
day)
Step 2: Peak Contaminant Flux Calculation (rβ)
To find the location of maximum radial flux, differentiate J(r)=βD0β[rln(r)βrln(R0β)] using the Product Rule:
drdJβ=βD0β[(1)ln(R0βrβ)+rβ
r1β]=βD0β[ln(R0βrβ)+1]
Setting drdJβ=0:
ln(R0βrβ)+1=0βΉln(R0βrβ)=β1βΉR0βrβ=eβ1=e1β
rβ=eR0ββ=2.71828100.0ββ36.79Β meters
Evaluating the maximum flux at rβ:
Jmaxβ=J(eR0ββ)=βD0β(eR0ββ)ln(eβ1)=βD0β(eR0ββ)(β1)=D0βeR0ββ
Substituting D0β=1.80Β g/(mβ
day) and R0β=100.0Β m:
Jmaxβ=1.80β
e100.0β=e180.0ββ66.22Β g/(mβ
day)
Step 3: Engineering Analysis & Filter Pack Sizing
- Boundary Behavior vs. Peak Flux: At the aquifer capture perimeter (r=R0β=100Β m), ln(1)=0βΉJ(100)=0. As groundwater travels inward, flux increases, reaching a maximum of 66.22Β g/(mβ
day) at rβ36.8Β m, and then decreases smoothly back to zero as rβ0+.
- Why limrβ0+βJ(r)=0 Matters: If J(r) diverged to β at the well screen (rβ0), the massive concentration gradient would cause local supersaturation of heavy metals and dissolved solids, cementing the sand pack with mineral scale. Because the flux mathematically approaches 0, the cylindrical surface area of the well screen (A=2ΟrL) is sufficient to absorb incoming groundwater smoothly. Environmental engineers can use standard silica sand filter packs and schedule periodic mild surfactant flushes without fear of localized structural clogging.
Engineering Conclusion
In environmental hydrology, products of decaying distances and logarithmic driving potentials frequently generate 0β
β indeterminate forms near point sinks and source boundaries. Relying on intuition might suggest the singularity ln(r)βββ dominates, predicting runaway solute buildup.
By inverting the linear factor r to rβ1 and applying L'HΓ΄pital's Rule, engineers prove that the linear convergence of distance to zero (rβ0) completely overpowers the weak logarithmic divergence (lnrβββ). This confirms that the contaminant flux vanishes at the borehole axis (Jboundaryβ=0). This guarantees that extraction well screens will not experience catastrophic chemical encrustation, providing rigorous mathematical validation for long-term municipal groundwater remediation designs.